0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G5LA-14 DC24

G5LA-14 DC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    G5LA-14 DC24

  • 数据手册
  • 价格&库存
G5LA-14 DC24 数据手册
G5LA PCB Power Relay A Cubic, Single-pole 10A Power Relay • Economical cube relay with universal terminal footprint • Conforms to VDE0435 • UL recognized/CSA certified. • High switching power: 10A @ 250VAC • Withstands impulse of up to 4,500V • Coil power consumption: 360mW • UL Class F coil insulation type also available • Tracking resistance: CTI>250 RoHS Compliant ■Model Number Legend ■Application Examples • Home appliance G 5 L A -@ @ @ - @ - @ 1 2 3 4 • OA equipments 5 1. Number of poles 1: 1-pole 2. Contact Form None: SPDT (1c) A: SPST-NO (1a) 3. Enclosure rating None: Flux protection 4: Fully sealed 4. Classification None: Standard E: High capacity (NC side) G 5 L A • Vending machines, etc. 5. UL Insulation System None: Standard CF: Class F ■Ordering Information Classification Terminal Shape Contact form SPST-NO (1a) Standard PCB terminals High-capacity SPDT (1c) SPDT (1c) Enclosure rating Model Flux protection G5LA-1A(-CF) Fully-sealed G5LA-1A4(-CF) Flux protection G5LA-1(-CF) Fully-sealed G5LA-14(-CF) Flux protection G5LA-1-E(-CF) Fully-sealed G5LA-14-E(-CF) Rated coil voltage 5VDC 9VDC 12VDC 24VDC 48VDC Minimum packing unit 100 pcs/tray Note. When ordering, add the rated coil voltage to the model number. Example: G5LA-1 DC 12 Rated coil voltage ■Ratings ●Coil Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 5 72 69.4 9 40 225 12 30 400 24 15 1600 48 10 4800 Must operate voltage (V) Must release voltage (V) Max. voltage (V) % of rated voltage 75% max. 10% min. 130% (at 85°C) 170% (at 23°C) Power consumption (mW) Approx. 360 Approx. 480 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±10%. 2. Please avoid ultrasonic cleaning this relay. 1 G5LA PCB Power Relay ●Contacts Item Standard model Contact material Ag-alloy (Cd free) Load Resistive load (cosφ=1) High-capacity (-E) model NO 10A at 250VAC 10A at 24VDC NO/NC 5A/5A at 125VAC 5A/5A at 24VDC 5A/5A at 250VAC 5A/5A at 24VDC Rate carry current 10A (NO), 5A (NC) 10A Max. switching voltage 250VAC, 24VDC Max. switching current 10A (NO), 5A (NC) Rated load NO AC2,500VA, DC240W NO/NC AC625VA, DC120W 10A Max. switching power Failure rate (reference value) AC1,250VAC, DC120W 100mA at 5VDC -5 Note. P level: λ60 = 0.1 x 10 /operation ■Characteristics G 5 L A Contact resistance 100 mΩ max. Operate time 10 ms max. Release time 5 ms max. Max. switching frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulaion resistance 1,000 mΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 1mA 50/60Hz for 1 min between coil and contacts 750 VAC 1mA 50/60Hz for 1 min between contacts of same polarity Vibration resistance Destruction: 10 to 55Hz, 1.5mm double amplitude Malfunction: 10 to 55Hz, 1.5mm double amplitude Shock resistance Destruction: 1,000m/s2(approx. 100G) Malfunction: 100 m/s2(approx. 10G) Endurance Mechanical: 10,000,000 operations min. Electrical: Approx. 100,000 operations Ambient operating temperature -40° to 85° (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 7.5g Note. Values in the above table are the initial values. 2 G5LA PCB Power Relay ■Engineering Data ●Durability (NO) (Average value) ●Ambient Temperature vs. Maximum Coil Voltage Note. The 120 VAC resistive load service life curve also applies for 250 VAC resistive load. Durability (x103 operations) ●Maximum switching capacity (NO) G 5 L A Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage not a continuous voltage. 3 G5LA PCB Power Relay ■Dimensions Note. All units are in millimeters unless otherwise indicated. G5LA-1(-CF) G5LA-14(-CF) G5LA-1-E(-CF) G5LA-14-E(-CF) +0.2 0 1.1 1.3 +0.2 0 3.3 1.4 2 @0.5 0.4 12.2 1.2 4 15.8 MAX (15.6)* +0.2 0 12 ± 0.1 1.1 +0.2 0 2 1 3.3 0.4 1.3 1.4 1 Terminal Arrangement/Internal Connections (Bottom View) 1.8 15.8 MAX (15.6)* PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm Unless specified 2-∅ 4 5 12.2 ± 0.1 12 2-∅ 19.8 MAX (19.6)* 1 0.4 G5LA-1A(-CF) G 5 G5LA-1A4(-CF) L A @0.5 12.2 3 2 ± 0.1 1 19.8 MAX (19.6)* 0.28 2 2 0.4 3-∅ 12 ± 0.1 2-∅ 0.28 Terminal Arrangement/Internal Connections (Bottom View) 1.8 15.8 MAX (15.6)* PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm Unless specified 0.4 2 ± 0.1 1.2 12 15.8 MAX (15.6)* 12.2 ± 0.1 5 3 G5LA PCB Power Relay ■Approved Standards ●UL Recognized (File No. E41643) Model Contact form Coil ratings Contact ratings 10 A, 277 VAC, general use, 40°C 10 A, 30 VDC, resistive, 40°C SPDT-NO (1a) SPST-NO (1a) G5LA 1/2 HP, 125-250VAC, 40°C 5 to 48 VDC 100,000 50,000 1,000 10 A, 277 VAC, general use, 85°C (-CF type only) 200 W Tungsten, 125 VAC, 40°C 10 A, 125 VAC, resistive, 40°C 10 A, 277 VAC, general use, 40°C (-E type only) SPDT-NC (1b) Number of test operations 10A, 24 VDC, resistive, 40°C (-E type only) 50,000 100,000 6,000 100,000 ●CSA Certified (File No. LR31928) Model Contact form Coil ratings Contact ratings 10 A, 277 VAC, general use, 40°C G5LA SPDT-NO (1a) SPST-NO (1a) 10 A, 24 VDC, resistive, 40°C 5 to 48 VDC 1/2 HP, 125-250VAC, 40°C 6,000 1,000 10 A, 277 VAC, general use, 85°C (-CF type only) 10 A, 125 VAC, resistive, 40°C SPDT-NC (1b) Number of test operations 6,000 ●VDE Certified (Approval No. 40017051) Model Contact form Coil ratings Contact ratings 10 A, 250 VAC, resistive, 85°C (flux protection) SPDT-NO (1a) SPST-NO (1a) G5LA SPDT (1c) 10 A, 250 VAC, resistive, 85°C (fully sealed) 5, 9, 12, 24, 48 VDC 12 A, 250 VAC, resistive, 85°C Number of test operations 50,000 10,000 5 A, 250 VAC, resistive, 85°C (flux protection) 50,000 5 A, 250 VAC, resistive, 85°C (fully sealed) 10,000 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. J184-E1-02 0113(1012)(O) 5 G 5 L A
G5LA-14 DC24 价格&库存

很抱歉,暂时无法提供与“G5LA-14 DC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货
G5LA-14 DC24
    •  国内价格
    • 66+10.99847
    • 300+10.64652
    • 1000+10.20658
    • 3000+9.50268
    • 8000+9.06274

    库存:68570